<p>Software version: 83, oil sense must be 485 serial port Protocol 91, baud rate 9600, address bit 1, or address bit 2</p> <p><img src="https://www.showdoc.com.cn/server/api/attachment/visitfile/sign/27fcd705ed84adbd81b9786c6376669c" alt="" /></p> <p>When the address bit is 1 Send:ASCII: *UL21201#29 (对应Hex指令:2a 55 4c 32 31 32 30 31 23 32 39 20) <img src="https://www.showdoc.com.cn/server/api/attachment/visitfile/sign/a4b7cb2a1b918f049be8c50b3ff12e6f" alt="" /></p> <p><img src="https://www.showdoc.com.cn/server/api/attachment/visitfile/sign/f7dc978bb438bca870300ed94b963f65" alt="" /></p> <p>*<em>UL212 reply:</em>TE,83,01,0133,1475,6900,0133,1476,0614,0,2801#2F**</p> <p><img src="https://www.showdoc.com.cn/server/api/attachment/visitfile/sign/1e83ecea60e2249d7613515680ce8384" alt="" /></p> <p>When the address bit is 2 Send: ASCII: *UL21202#2A (对应Hex指令:2a 55 4c 32 31 32 30 32 23 32 41)</p> <p>So,When the address bits are different, an exclusive OR check is required to obtain the HEX instruction before sending</p>