Change to LLS Protocol

<p>Step1: Connect Black box with Computer via RS232-USB cable</p> <p>Step2: Download the configure software from this link below:</p> <p>UL202, 1 Meter: <a href="https://we.tl/t-QIDjjFSByv">https://we.tl/t-QIDjjFSByv</a> UL202-E, 2.5meter: <a href="https://we.tl/t-DCCiBMNK4k">https://we.tl/t-DCCiBMNK4k</a></p> <p>Step3: Configure the sensor as below to work with Omnicomm LLS protoco: Baud Rate:19200 Protoco:16 Netaddress: 1 <img src="https://www.showdoc.cc/server/api/common/visitfile/sign/e236f0933f500bcb2638828f61ed4914?showdoc=.jpg" alt="" /></p> <ol> <li> <p>After upgrade to LLS protocol, the sensor will output data automatically in 0x07 command.</p> </li> <li>If you need make the sensor work in passive way, you just need send 0x06 command to sensor, and sensor will only output fuel data after receiving commands from GPS tracker. For example, the Net address is 01 GPS Tracker send command to UL202-LLS: 31 01 06 6C</li> </ol> <p>If Net Address is 02 GPS Tracker send command to UL202-LLS: 31 02 06 39</p> <p>With regards to LLS protocol, please refer to this: <a href="https://doc.omnicomm.ru/en/lls_integration/binary/single-reading">https://doc.omnicomm.ru/en/lls_integration/binary/single-reading</a> Right now, we support 06h, 07h command</p>