Minimum basic information
<p><strong>Brief Description:</strong></p>
<ul>
<li>Data return format for basic information of min devices and description of some basic information parameters</li>
<li><code>Only applicable for: batch retrieval of basic device information.</code></li>
</ul>
<p><strong>Return Example</strong></p>
<pre><code>{
&quot;code&quot;: 0,
&quot;data&quot;: {
&quot;min&quot;: [
{
&quot;id&quot;: 1627,
&quot;serialNum&quot;: &quot;AFE494403F&quot;,
&quot;portName&quot;: &quot;ShinePano - BLE094404C&quot;,
&quot;dataLogSn&quot;: &quot;BLE094404C&quot;,
&quot;groupId&quot;: -1,
&quot;alias&quot;: &quot;AFE494403F&quot;,
&quot;location&quot;: &quot;&quot;,
&quot;addr&quot;: 1,
&quot;fwVersion&quot;: &quot;AK1.0&quot;,
&quot;model&quot;: 720575940630937650,
&quot;innerVersion&quot;: &quot;AKAA0501&quot;,
&quot;lost&quot;: false,
&quot;status&quot;: 1,
&quot;tcpServerIp&quot;: &quot;47.119.160.91&quot;,
&quot;lastUpdateTime&quot;: 1716535759000,
&quot;sysTime&quot;: &quot;&quot;,
&quot;deviceType&quot;: 0,
&quot;communicationVersion&quot;: &quot;ZAAA-0004&quot;,
&quot;pmax&quot;: 5000,
&quot;comAddress&quot;: 1,
&quot;dtc&quot;: 5200,
&quot;countrySelected&quot;: 0,
&quot;startTime&quot;: 30,
&quot;restartTime&quot;: 60,
&quot;wselectBaudrate&quot;: 0,
&quot;trakerModel&quot;: 0,
&quot;priorityChoose&quot;: 0,
&quot;batteryType&quot;: 0,
&quot;batSeriesNum&quot;: 0,
&quot;batParallelNum&quot;: 0,
&quot;bctMode&quot;: 0,
&quot;bctAdjust&quot;: 0,
&quot;bagingTestStep&quot;: 0,
&quot;vnormal&quot;: 1000.0,
&quot;mppt&quot;: 513.0,
&quot;batTempLowerLimitD&quot;: 0.0,
&quot;batTempUpperLimitD&quot;: 0.0,
&quot;batTempLowerLimitC&quot;: 0.0,
&quot;batTempUpperLimitC&quot;: 0.0,
&quot;vbatWarning&quot;: 0.0,
&quot;vbatWarnClr&quot;: 0.0,
&quot;modbusVersion&quot;: 305,
&quot;manufacturer&quot;: &quot; PV Inverter &quot;,
&quot;bdc1Sn&quot;:&quot;����������������&quot;,
&quot;bdc1Model&quot;: &quot;0&quot;,
&quot;bdc1Version&quot;:&quot;����-0&quot;,
&quot;vbatStopForDischarge&quot;: 0.0,
&quot;vbatStopForCharge&quot;: 0.0,
&quot;vbatStartForDischarge&quot;: 0.0,
&quot;userName&quot;: null,
&quot;modelText&quot;: &quot;S0AB00D00T00P0FU00M0032&quot;,
&quot;plantId&quot;: 0,
&quot;plantname&quot;: null,
&quot;timezone&quot;: 8.0,
&quot;pCharge&quot;: 0.0,
&quot;pDischarge&quot;: 0.0,
&quot;updating&quot;: false,
&quot;record&quot;: null,
&quot;power&quot;: 0.0,
&quot;eToday&quot;: 0.0,
&quot;eTotal&quot;: 0.0,
&quot;tlxSetbean&quot;: null,
&quot;powerMax&quot;: null,
&quot;powerMaxTime&quot;: null,
&quot;energyDayMap&quot;: {},
&quot;energyMonth&quot;: 0.0,
&quot;optimezerList&quot;: null,
&quot;strNum&quot;: -1,
&quot;liBatteryManufacturers&quot;: &quot;&quot;,
&quot;liBatteryFwVersion&quot;: &quot;&quot;,
&quot;bmsSoftwareVersion&quot;: &quot;&quot;,
&quot;bmsCommunicationType&quot;: 0,
&quot;monitorVersion&quot;: &quot;null&quot;,
&quot;bdcMode&quot;: 0,
&quot;bdcAuthversion&quot;: 0,
&quot;hwVersion&quot;: &quot;null&quot;,
&quot;vppOpen&quot;: 0,
&quot;level&quot;: 4,
&quot;lastUpdateTimeText&quot;: &quot;2024-05-24 15:29:19&quot;,
&quot;children&quot;: null,
&quot;treeName&quot;: &quot;AFE494403F&quot;,
&quot;treeID&quot;: &quot;ST_AFE494403F&quot;,
&quot;parentID&quot;: &quot;LIST_BLE094404C_22&quot;,
&quot;imgPath&quot;: &quot;./css/img/status_gray.gif&quot;,
&quot;statusText&quot;: &quot;tlx.status.checking&quot;,
&quot;powerMaxText&quot;: &quot;&quot;,
&quot;energyMonthText&quot;: &quot;0&quot;
}
]
},
&quot;message&quot;: &quot;SUCCESSFUL_OPERATION&quot;
}</code></pre>
<p><strong>Return Parameter Description</strong></p>
<table>
<thead>
<tr>
<th style="text-align: left;">Parameter Name</th>
<th style="text-align: left;">Type</th>
<th>Description</th>
</tr>
</thead>
<tbody>
<tr>
<td style="text-align: left;">serialNum</td>
<td style="text-align: left;">string</td>
<td>Device SN</td>
</tr>
<tr>
<td style="text-align: left;">lost</td>
<td style="text-align: left;">string</td>
<td>Device online status (0: Online, 1: Offline)</td>
</tr>
<tr>
<td style="text-align: left;">status</td>
<td style="text-align: left;">int</td>
<td>Device status (0: Waiting mode, 1: Self-check mode, 3: Fault mode, 4: Upgrading, 5,6,7,8: Normal mode)</td>
</tr>
<tr>
<td style="text-align: left;">alias</td>
<td style="text-align: left;">int</td>
<td>Alias</td>
</tr>
<tr>
<td style="text-align: left;">location</td>
<td style="text-align: left;">string</td>
<td>Address</td>
</tr>
<tr>
<td style="text-align: left;">dataLogSn</td>
<td style="text-align: left;">string</td>
<td>Data logger serial number</td>
</tr>
<tr>
<td style="text-align: left;">pmax</td>
<td style="text-align: left;">string</td>
<td>Rated power</td>
</tr>
<tr>
<td style="text-align: left;">power</td>
<td style="text-align: left;">string</td>
<td>Current power</td>
</tr>
<tr>
<td style="text-align: left;"><del>eToday</del></td>
<td style="text-align: left;">string</td>
<td><del>Today's generated power</del> (Deprecated)</td>
</tr>
<tr>
<td style="text-align: left;"><del>eTotal</del></td>
<td style="text-align: left;">string</td>
<td><del>Total generated power</del> (Deprecated)</td>
</tr>
<tr>
<td style="text-align: left;">lastUpdateTime</td>
<td style="text-align: left;">string</td>
<td>Last update time</td>
</tr>
<tr>
<td style="text-align: left;">tcpServerIp</td>
<td style="text-align: left;">string</td>
<td>Server address</td>
</tr>
<tr>
<td style="text-align: left;">fwVersion</td>
<td style="text-align: left;">string</td>
<td>Inverter version</td>
</tr>
<tr>
<td style="text-align: left;">addr = 0</td>
<td style="text-align: left;">string</td>
<td>Inverter address</td>
</tr>
<tr>
<td style="text-align: left;">model</td>
<td style="text-align: left;">string</td>
<td>Model</td>
</tr>
<tr>
<td style="text-align: left;">innerVersion</td>
<td style="text-align: left;">string</td>
<td>Internal version number</td>
</tr>
<tr>
<td style="text-align: left;">sysTime</td>
<td style="text-align: left;">string</td>
<td>System time</td>
</tr>
<tr>
<td style="text-align: left;">deviceType</td>
<td style="text-align: left;">string</td>
<td>1:Mix, 0: Inverter</td>
</tr>
<tr>
<td style="text-align: left;">communicationVersion</td>
<td style="text-align: left;">string</td>
<td>Communication version number</td>
</tr>
<tr>
<td style="text-align: left;">pmax</td>
<td style="text-align: left;">string</td>
<td>Rated power; 0.1VA</td>
</tr>
<tr>
<td style="text-align: left;">comAddress</td>
<td style="text-align: left;">string</td>
<td>Communication address 30</td>
</tr>
<tr>
<td style="text-align: left;">dtc</td>
<td style="text-align: left;">string</td>
<td>Device code</td>
</tr>
<tr>
<td style="text-align: left;">countrySelected</td>
<td style="text-align: left;">string</td>
<td>Country selection</td>
</tr>
<tr>
<td style="text-align: left;">startTime</td>
<td style="text-align: left;">string</td>
<td>Startup countdown</td>
</tr>
<tr>
<td style="text-align: left;">restartTime</td>
<td style="text-align: left;">string</td>
<td>Reconnection countdown</td>
</tr>
<tr>
<td style="text-align: left;">wselectBaudrate</td>
<td style="text-align: left;">string</td>
<td>Baud rate selection</td>
</tr>
<tr>
<td style="text-align: left;">trakerModel</td>
<td style="text-align: left;">string</td>
<td>Task model</td>
</tr>
<tr>
<td style="text-align: left;">priorityChoose</td>
<td style="text-align: left;">string</td>
<td>Energy priority selection; 0: Load, 1: Battery, 2: Grid</td>
</tr>
<tr>
<td style="text-align: left;">batteryType</td>
<td style="text-align: left;">string</td>
<td>Battery type selection; 0: Lithium, 1: Lead-acid, 2: Other</td>
</tr>
<tr>
<td style="text-align: left;">batSeriesNum</td>
<td style="text-align: left;">string</td>
<td>Number of battery series</td>
</tr>
<tr>
<td style="text-align: left;">batParallelNum</td>
<td style="text-align: left;">string</td>
<td>Number of battery parallels</td>
</tr>
<tr>
<td style="text-align: left;">bctMode</td>
<td style="text-align: left;">string</td>
<td>Sensor type; 2: METER, 1: Wireless CT, 0: Wired CT</td>
</tr>
<tr>
<td style="text-align: left;">bctAdjust</td>
<td style="text-align: left;">string</td>
<td>Sensor adjustment enable; 0: Disable, 1: Enable</td>
</tr>
<tr>
<td style="text-align: left;">bagingTestStep</td>
<td style="text-align: left;">string</td>
<td>Battery self-test; 0: Default, 1: Charge, 2: Discharge</td>
</tr>
<tr>
<td style="text-align: left;">vnormal</td>
<td style="text-align: left;">string</td>
<td>Rated PV voltage; 0.1V</td>
</tr>
<tr>
<td style="text-align: left;">mppt</td>
<td style="text-align: left;">string</td>
<td>MPPT voltage</td>
</tr>
<tr>
<td style="text-align: left;">batTempLowerLimitD</td>
<td style="text-align: left;">string</td>
<td>Battery discharge lower temperature limit; 0.1℃</td>
</tr>
<tr>
<td style="text-align: left;">batTempUpperLimitD</td>
<td style="text-align: left;">string</td>
<td>Battery discharge upper temperature limit; 0.1℃</td>
</tr>
<tr>
<td style="text-align: left;">batTempLowerLimitC</td>
<td style="text-align: left;">string</td>
<td>Battery charge lower temperature limit; 0.1℃</td>
</tr>
<tr>
<td style="text-align: left;">batTempUpperLimitC</td>
<td style="text-align: left;">string</td>
<td>Battery charge upper temperature limit; 0.1℃</td>
</tr>
<tr>
<td style="text-align: left;">vbatWarning</td>
<td style="text-align: left;">string</td>
<td>Battery low voltage warning point; 0.1V</td>
</tr>
<tr>
<td style="text-align: left;">vbatWarnClr</td>
<td style="text-align: left;">string</td>
<td>Battery low voltage recovery point; 0.1V</td>
</tr>
<tr>
<td style="text-align: left;">modbusVersion</td>
<td style="text-align: left;">string</td>
<td>Modbus version</td>
</tr>
<tr>
<td style="text-align: left;">manufacturer</td>
<td style="text-align: left;">string</td>
<td>Manufacturer code 34-41</td>
</tr>
<tr>
<td style="text-align: left;">bdc1Sn</td>
<td style="text-align: left;">string</td>
<td>BDC1 serial number</td>
</tr>
<tr>
<td style="text-align: left;">bdc1Model</td>
<td style="text-align: left;">string</td>
<td>BDC1 model</td>
</tr>
<tr>
<td style="text-align: left;">bdc1Version</td>
<td style="text-align: left;">string</td>
<td>BDC1 version</td>
</tr>
<tr>
<td style="text-align: left;">vbatStopForDischarge</td>
<td style="text-align: left;">string</td>
<td>Battery discharge stop voltage; 0.01V</td>
</tr>
<tr>
<td style="text-align: left;">vbatStopForCharge</td>
<td style="text-align: left;">string</td>
<td>Battery charge stop voltage; 0.01V</td>
</tr>
<tr>
<td style="text-align: left;">vbatStartForDischarge</td>
<td style="text-align: left;">string</td>
<td>Battery discharge lower limit voltage; 0.01V</td>
</tr>
<tr>
<td style="text-align: left;">modelText</td>
<td style="text-align: left;">string</td>
<td>Model</td>
</tr>
</tbody>
</table>
<p><strong>Notes</strong></p>
<ul>
<li>Retrieval frequency is once every 5 minutes or less</li>
</ul>