ShineServer_English version


Obtain smart meter data according to the collector

<p><strong>A brief description:</strong> </p> <p>-Interface to obtain smart meter data according to the collector SN and smart meter address -<code>Only applicable to devices with device type 3 returned in the 3.3 interface.</code></p> <p><strong>Request URL:</strong> -<code>http(s)://test.growatt.com/v1/device/ammeter/meter_data</code></p> <p><strong>How ​​to request:</strong> -get</p> <p><strong>Parameter:</strong></p> <table> <thead> <tr> <th style="text-align: left;">Parameter name</th> <th style="text-align: left;">Is it required</th> <th style="text-align: left;">Type</th> <th>Description</th> </tr> </thead> <tbody> <tr> <td style="text-align: left;">datalog_sn</td> <td style="text-align: left;">Yes</td> <td style="text-align: left;">string</td> <td>collector SN</td> </tr> <tr> <td style="text-align: left;">address</td> <td style="text-align: left;">Yes</td> <td style="text-align: left;">time</td> <td>device address</td> </tr> <tr> <td style="text-align: left;">start_date</td> <td style="text-align: left;">Yes</td> <td style="text-align: left;">time</td> <td>start date</td> </tr> <tr> <td style="text-align: left;">end_date</td> <td style="text-align: left;">Yes</td> <td style="text-align: left;">time</td> <td>End date (the date interval cannot exceed 7 days)</td> </tr> <tr> <td style="text-align: left;">page</td> <td style="text-align: left;">No</td> <td style="text-align: left;">int</td> <td>Page number, default 1</td> </tr> <tr> <td style="text-align: left;">perpage</td> <td style="text-align: left;">No</td> <td style="text-align: left;">int</td> <td>Number per page, default 20, maximum 100</td> </tr> </tbody> </table> <p><strong>Return example</strong></p> <pre><code>{ "data": { "count": 12, "meter_data": [ { "reactivePower": 155.8000030517578, "forwardActiveNeed": 0, "l3CurrentHarmonic": 0, "currentL3Need": 0, "voltageL1": 0, "activePower": 4886.5, "voltageL2": 0, "voltageL3": 0, "apparentEnergyNeed": 0, "voltageUbc": 0, "l2VoltageHarmonic3": 0, "gridEnergy": 0, "activePowerMaxNeedOne": 0, "activeEnergy": 32.5, "activePowerNeedOne": 0, "powerFactorL1": 0, "voltage": 0, "feiLvBoZEnergy": 9.5, "powerFactorL3": 0, "powerFactorL2": 0, "reverseActiveNeed": 0, "feiLvPingZEnergy": 4.900000095367432, "voltageUab": 0, "forwardActiveMaxNeed": 0, "bActivePower": 0, "totalReactiveEnergyL3": 0, "reverseActiveTotalEnergy": 0, "totalEnergy": 0, "totalReactiveEnergyL1": 0, "totalReactiveEnergyL2": 0, "currentL3": 0, "cPowerFactor": 0, "apparentEnergy": 0, "aReactivePower": 0, "current": 0, "instantlyTotalActivePower": 0, "feiLvFengZEnergy": 6.800000190734863, "timeText": "2018-12-13 11:03:52", "dataLogSn": "CRAZT00001", "apparentEnergyMaxNeed": 0, "bReactivePower": 0, "posiActivePower": 0, "bPowerFactor": 0, "l3Voltage1": 0, "currentHarmonicAvg": 0, "currentL1": 0, "currentL2": 0, "currentMaxNeed": 0, "zeroLineMaxNeed": 0, "voltageUca": 0, "aPowerFactor": 0, "reactivePowerL2": 0, "reactivePowerL3": 0, "reactivePowerL1": 0, "currentL1Need": 0, "aCurrent": 0, "l3VoltageHarmonic1": 0, "addr": 1, "currentIc": 0, "l2VoltageHarmonic": 0, "currentIb": 0, "currentIa": 0, "positiveActiveTotalEnergy": 0, "powerFactor": 0.9991999864578247, "l2Voltage3": 0, "activePowerNeed": 0, "instantaneousTotalApparentPower": 0, "gridFrequency": 0, "aActivePower": 0, "lineVoltageHarmonicAvg": 0, "posiReactivePower": 0, "currentL1MaxNeed": 0, "apparentPowerL1": 0, "apparentPowerL2": 0, "apparentPowerL3": 0, "l2CurrentHarmonic": 0, "zeroLineNeed": 0, "cReactivePower": 0, "l1VoltageHarmonic2": 0, "activePowerL3": 0, "reactiveEnergy": 0.10000000149011612, "activePowerL1": 0, "l1CurrentHarmonic": 0, "l1VoltageHarmonic": 0, "activePowerL2": 0, "reverseActiveMaxNeed": 0, "cActivePower": 0, "frequency": 0, "currentL2MaxNeed": 0, "voltageHarmonicAvg": 0, "currentNeed": 0, "apparentPower": 5024.7998046875, "reverActivePower": 0, "currentL2Need": 0, "calendar": { "minimalDaysInFirstWeek": 1, "time": { "time": 1544670232000, "minutes": 3, "seconds": 52, "hours": 11, "month": 11, "timezoneOffset": -480, "year": 118, "day": 4, "date": 13 }, "weekYear": 2018, "weeksInWeekYear": 52, "gregorianChange": { "time": -12219292800000, "minutes": 0, "seconds": 0, "hours": 8, "month": 9, "timezoneOffset": -480,"year": -318, "day": 5, "date": 15 }, "timeZone": { "lastRuleInstance": null, "DSTSavings": 0, "rawOffset": 28800000, "ID": "Asia/Shanghai", "dirty": false, "displayName": "China Standard Time" }, "lenient": true, "timeInMillis": 1544670232000, "firstDayOfWeek": 1, "weekDateSupported": true }, "l1Voltage2": 0, "voltageUb": 0, "voltageUa": 0, "totalActiveEnergyL1": 0, "voltageUc": 0, "aVoltage": 0, "totalActiveEnergyL3": 0, "totalActiveEnergyL2": 0, "l3VoltageHarmonic": 0, "activePowerMaxNeed": 0, "feiLvGuZEnergy": 3.4000000953674316, "reverReactivePower": 0, "instantlyTotalReactivePower": 0, "userEnergy": 0, "currentL3MaxNeed": 0 } ], "datalogger_sn": "CRAZT00001" }, "error_code": 0, "error_msg": "" }</code></pre> <p><strong>Return parameter description</strong></p> <table> <thead> <tr> <th style="text-align: left;">Parameter name</th> <th style="text-align: left;">Type</th> <th>Description</th> </tr> </thead> <tbody> <tr> <td style="text-align: left;">dataLogSn</td> <td style="text-align: left;">int</td> <td>The collector SN of the smart meter</td> </tr> <tr> <td style="text-align: left;">datalogger_sn</td> <td style="text-align: left;">string</td> <td>Collector serial number</td> </tr> <tr> <td style="text-align: left;">addr</td> <td style="text-align: left;">string</td> <td>Smart meter device address</td> </tr> <tr> <td style="text-align: left;">timeText</td> <td style="text-align: left;">string</td> <td>Last update time</td> </tr> <tr> <td style="text-align: left;">Smart Meter Data</td> <td style="text-align: left;"></td> <td></td> </tr> <tr> <td style="text-align: left;">reactivePower</td> <td style="text-align: left;">int</td> <td>reactive power</td> </tr> <tr> <td style="text-align: left;">reactiveEnergy</td> <td style="text-align: left;">int</td> <td>Reactive energy</td> </tr> <tr> <td style="text-align: left;">gridEnergy</td> <td style="text-align: left;">string</td> <td>Grid-side electricity</td> </tr> <tr> <td style="text-align: left;">totalEnergy</td> <td style="text-align: left;">string</td> <td>Total energy of the meter</td> </tr> <tr> <td style="text-align: left;">feiLvGuZEnergy</td> <td style="text-align: left;">string</td> <td>Rate Valley Positive Active Power</td> </tr> <tr> <td style="text-align: left;">activeEnergy</td> <td style="text-align: left;">string</td> <td>active energy</td> </tr> <tr> <td style="text-align: left;">activePower</td> <td style="text-align: left;">string</td> <td>active power</td> </tr> <tr> <td style="text-align: left;">feiLvBoZEnergy</td> <td style="text-align: left;">string</td> <td>Rate wave forward active power</td> </tr> <tr> <td style="text-align: left;">powerFactor</td> <td style="text-align: left;">string</td> <td>Power factor</td> </tr> <tr> <td style="text-align: left;">userEnergy</td> <td style="text-align: left;">string</td> <td>User-side power</td> </tr> <tr> <td style="text-align: left;">apparentPower</td> <td style="text-align: left;">string</td> <td>Apparent Power</td> </tr> <tr> <td style="text-align: left;">feiLvFengZEnergy</td> <td style="text-align: left;">string</td> <td>Rate peak positive active power</td> </tr> <tr> <td style="text-align: left;">feiLvPingZEnergy</td> <td style="text-align: left;">string</td> <td>The rate is flat positive active power</td> </tr> <tr> <td style="text-align: left;">SDM one-way meter</td> <td style="text-align: left;"></td> <td></td> </tr> <tr> <td style="text-align: left;">activeEnergy</td> <td style="text-align: left;">int</td> <td>Total active energy</td> </tr> <tr> <td style="text-align: left;">reactiveEnergy</td> <td style="text-align: left;">int</td> <td>Total reactive energy</td> </tr> <tr> <td style="text-align: left;">activePower</td> <td style="text-align: left;">int</td> <td>active power</td> </tr> <tr> <td style="text-align: left;">reactivePower</td> <td style="text-align: left;">int</td> <td>reactive power</td> </tr> <tr> <td style="text-align: left;">apparentPower</td> <td style="text-align: left;">string</td> <td>Apparent Power</td> </tr> <tr> <td style="text-align: left;">powerFactor</td> <td style="text-align: left;">string</td> <td>Power factor</td> </tr> <tr> <td style="text-align: left;">voltage</td> <td style="text-align: left;">int</td> <td>voltage</td> </tr> <tr> <td style="text-align: left;">current</td> <td style="text-align: left;">int</td> <td>current</td> </tr> <tr> <td style="text-align: left;">frequency</td> <td style="text-align: left;">int</td> <td>frequency</td> </tr> <tr> <td style="text-align: left;">posiActivePower</td> <td style="text-align: left;">int</td> <td>Positive active power</td> </tr> <tr> <td style="text-align: left;">reverActivePower</td> <td style="text-align: left;">int</td> <td>reverse active power</td> </tr> <tr> <td style="text-align: left;">posiReactivePower</td> <td style="text-align: left;">int</td> <td>Positive reactive power</td> </tr> <tr> <td style="text-align: left;">reverReactivePower</td> <td style="text-align: left;">int</td> <td>Reverse reactive power</td> </tr> <tr> <td style="text-align: left;">totalEnergy</td> <td style="text-align: left;">int</td> <td>Total Energy</td> </tr> <tr> <td style="text-align: left;">activePowerNeedOne</td> <td style="text-align: left;">int</td> <td>Total active power demand</td> </tr> <tr> <td style="text-align: left;">activePowerMaxNeedOne</td> <td style="text-align: left;">int</td> <td>Maximum total active power demand</td> </tr> <tr> <td style="text-align: left;">forwardActiveNeed</td> <td style="text-align: left;">int</td> <td>forward active power demand</td> </tr> <tr> <td style="text-align: left;">forwardActiveMaxNeed</td> <td style="text-align: left;">int</td> <td>Maximum forward active power demand</td> </tr> <tr> <td style="text-align: left;">reverseActiveNeed</td> <td style="text-align: left;">int</td> <td>reverse active power demand</td> </tr> <tr> <td style="text-align: left;">reverseActiveMaxNeed</td> <td style="text-align: left;">int</td> <td>Maximum reverse active power demand</td> </tr> <tr> <td style="text-align: left;">currentNeed</td> <td style="text-align: left;">int</td> <td>Current demand</td> </tr> <tr> <td style="text-align: left;">currentMaxNeed</td> <td style="text-align: left;">int</td> <td>Maximum current demand</td> </tr> <tr> <td style="text-align: left;">SDM three-way meter</td> <td style="text-align: left;"></td> <td></td> </tr> <tr> <td style="text-align: left;">activeEnergy</td> <td style="text-align: left;">int</td> <td>Total active energy</td> </tr> <tr> <td style="text-align: left;">reactiveEnergy</td> <td style="text-align: left;">int</td> <td>Total reactive energy</td> </tr> <tr> <td style="text-align: left;">activePowerL1</td> <td style="text-align: left;">int</td> <td>active power L1</td> </tr> <tr> <td style="text-align: left;">activePowerL2</td> <td style="text-align: left;">int</td> <td>active power L2</td> </tr> <tr> <td style="text-align: left;">activePowerL3</td> <td style="text-align: left;">int</td> <td>active power L3</td> </tr> <tr> <td style="text-align: left;">reactivePowerL1</td> <td style="text-align: left;">int</td> <td>Reactive Power L1</td> </tr> <tr> <td style="text-align: left;">reactivePowerL2</td> <td style="text-align: left;">int</td> <td>Reactive Power L2</td> </tr> <tr> <td style="text-align: left;">reactivePowerL3</td> <td style="text-align: left;">int</td> <td>Reactive Power L3</td> </tr> <tr> <td style="text-align: left;">apparentPowerL1</td> <td style="text-align: left;">int</td> <td>Apparent Power L1</td> </tr> <tr> <td style="text-align: left;">apparentPowerL2</td> <td style="text-align: left;">int</td> <td>Apparent Power L2</td> </tr> <tr> <td style="text-align: left;">apparentPowerL3</td> <td style="text-align: left;">int</td> <td>Apparent Power L3</td> </tr> <tr> <td style="text-align: left;">powerFactorL1</td> <td style="text-align: left;">int</td> <td>Power Factor L1</td> </tr> <tr> <td style="text-align: left;">powerFactorL2</td> <td style="text-align: left;">int</td> <td>Power Factor L2</td> </tr> <tr> <td style="text-align: left;">powerFactorL3</td> <td style="text-align: left;">int</td> <td>Power Factor L3</td> </tr> <tr> <td style="text-align: left;">voltageL1</td> <td style="text-align: left;">int</td> <td>voltage L1</td> </tr> <tr> <td style="text-align: left;">voltageL2</td> <td style="text-align: left;">int</td> <td>voltage L2</td> </tr> <tr> <td style="text-align: left;">voltageL3</td> <td style="text-align: left;">int</td> <td>voltage L3</td> </tr> <tr> <td style="text-align: left;">currentL1</td> <td style="text-align: left;">int</td> <td>current L1</td> </tr> <tr> <td style="text-align: left;">currentL2</td> <td style="text-align: left;">int</td> <td>Current L2</td> </tr> <tr> <td style="text-align: left;">currentL3</td> <td style="text-align: left;">int</td> <td>current L3</td> </tr> <tr> <td style="text-align: left;">activePower</td> <td style="text-align: left;">int</td> <td>Total active power</td> </tr> <tr> <td style="text-align: left;">apparentPower</td> <td style="text-align: left;">int</td> <td>Total apparent power</td> </tr> <tr> <td style="text-align: left;">reactivePower</td> <td style="text-align: left;">int</td> <td>Total reactive power</td> </tr> <tr> <td style="text-align: left;">powerFactor</td> <td style="text-align: left;">int</td> <td>Total power factor</td> </tr> <tr> <td style="text-align: left;">frequency</td> <td style="text-align: left;">int</td> <td>frequency</td> </tr> <tr> <td style="text-align: left;">posiActivePower</td> <td style="text-align: left;">int</td> <td>Positive active power</td> </tr> <tr> <td style="text-align: left;">reverActivePower</td> <td style="text-align: left;">int</td> <td>reverse active power</td> </tr> <tr> <td style="text-align: left;">posiReactivePower</td> <td style="text-align: left;">int</td> <td>Positive reactive power</td> </tr> <tr> <td style="text-align: left;">reverReactivePower</td> <td style="text-align: left;">int</td> <td>Reverse reactive power</td> </tr> <tr> <td style="text-align: left;">apparentEnergy</td> <td style="text-align: left;">int</td> <td>apparent energy</td> </tr> <tr> <td style="text-align: left;">totalActiveEnergyL1</td> <td style="text-align: left;">int</td> <td>total active energy L1</td> </tr> <tr> <td style="text-align: left;">totalActiveEnergyL2</td> <td style="text-align: left;">int</td> <td>total active energy L2</td> </tr> <tr> <td style="text-align: left;">totalActiveEnergyL3</td> <td style="text-align: left;">int</td> <td>total active energy L3</td> </tr> <tr> <td style="text-align: left;">totalReactiveEnergyL1</td> <td style="text-align: left;">int</td> <td>total reactive energy L1</td> </tr> <tr> <td style="text-align: left;">totalReactiveEnergyL2</td> <td style="text-align: left;">int</td> <td>total reactive energy L2</td> </tr> <tr> <td style="text-align: left;">totalReactiveEnergyL3</td> <td style="text-align: left;">int</td> <td>total reactive energy L3</td> </tr> <tr> <td style="text-align: left;">totalEnergy</td> <td style="text-align: left;">int</td> <td>Total Energy</td> </tr> <tr> <td style="text-align: left;">L1Voltage2</td> <td style="text-align: left;">int</td> <td>L1-2 line voltage</td> </tr> <tr> <td style="text-align: left;">l2Voltage3</td> <td style="text-align: left;">int</td> <td>L2-3 line voltage</td> </tr> <tr> <td style="text-align: left;">L3Voltage1</td> <td style="text-align: left;">int</td> <td>L3-1 line voltage</td> </tr> <tr> <td style="text-align: left;">currentL1Need</td> <td style="text-align: left;">int</td> <td>Current L1 current demand</td> </tr> <tr> <td style="text-align: left;">currentL2Need</td> <td style="text-align: left;">int</td> <td>Current L2 current demand</td> </tr> <tr> <td style="text-align: left;">currentL3Need</td> <td style="text-align: left;">int</td> <td>Current L3 current demand</td> </tr> <tr> <td style="text-align: left;">currentL1MaxNeed</td> <td style="text-align: left;">int</td> <td>L1 current maximum demand</td> </tr> <tr> <td style="text-align: left;">currentL2MaxNeed</td> <td style="text-align: left;">int</td> <td>L2 current maximum demand</td> </tr> <tr> <td style="text-align: left;">currentL3MaxNeed</td> <td style="text-align: left;">int</td> <td>L3 current maximum demand</td> </tr> <tr> <td style="text-align: left;">activePowerNeed</td> <td style="text-align: left;">int</td> <td>Current total active power demand</td> </tr> <tr> <td style="text-align: left;">activePowerMaxNeed</td> <td style="text-align: left;">int</td> <td>Total active power maximum demand</td> </tr> <tr> <td style="text-align: left;">apparentEnergyNeed</td> <td style="text-align: left;">int</td> <td>Current total apparent power demand</td> </tr> <tr> <td style="text-align: left;">apparentEnergyMaxNeed</td> <td style="text-align: left;">int</td> <td>Current total apparent power maximum demand</td> </tr> <tr> <td style="text-align: left;">zeroLineNeed</td> <td style="text-align: left;">int</td> <td>The current zero line current demand</td> </tr> <tr> <td style="text-align: left;">zeroLineMaxNeed</td> <td style="text-align: left;">int</td> <td>zero line current maximum demand</td> </tr> <tr> <td style="text-align: left;">l1VoltageHarmonic</td> <td style="text-align: left;">int</td> <td>L1 phase voltage total harmonic content</td> </tr> <tr> <td style="text-align: left;">l2VoltageHarmonic</td> <td style="text-align: left;">int</td> <td>L2 phase voltage total harmonic content</td> </tr> <tr> <td style="text-align: left;">l3VoltageHarmonic</td> <td style="text-align: left;">int</td> <td>L3 phase voltage total harmonic content</td> </tr> <tr> <td style="text-align: left;">l1CurrentHarmonic</td> <td style="text-align: left;">int</td> <td>L1 current total harmonic content</td> </tr> <tr> <td style="text-align: left;">l2CurrentHarmonic</td> <td style="text-align: left;">int</td> <td>L2 current total harmonic content</td> </tr> <tr> <td style="text-align: left;">l3CurrentHarmonic</td> <td style="text-align: left;">int</td> <td>L3 current total harmonic content</td> </tr> <tr> <td style="text-align: left;">voltageHarmonicAvg</td> <td style="text-align: left;">int</td> <td>Average value of total harmonic content of three-phase voltage</td> </tr> <tr> <td style="text-align: left;">currentHarmonicAvg</td> <td style="text-align: left;">int</td> <td>Average value of total harmonic content of three-phase current</td> </tr> <tr> <td style="text-align: left;">l1VoltageHarmonic2</td> <td style="text-align: left;">int</td> <td>L1-2 line voltage total harmonic content</td> </tr> <tr> <td style="text-align: left;">l2VoltageHarmonic3</td> <td style="text-align: left;">int</td> <td>L2-3 line voltage total harmonic content</td> </tr> <tr> <td style="text-align: left;">l3VoltageHarmonic1</td> <td style="text-align: left;">int</td> <td>L3-1 line voltage total harmonic content</td> </tr> <tr> <td style="text-align: left;">lineVoltageHarmonicAvg</td> <td style="text-align: left;">int</td> <td>Average value of total harmonic content of three-phase line voltage</td> </tr> <tr> <td style="text-align: left;">CHNT one-way meter</td> <td style="text-align: left;"></td> <td></td> </tr> <tr> <td style="text-align: left;">aVoltage</td> <td style="text-align: left;">int</td> <td>Phase A voltage</td> </tr> <tr> <td style="text-align: left;">aCurrent</td> <td style="text-align: left;">int</td> <td>A phase current</td> </tr> <tr> <td style="text-align: left;">instantlyTotalActivePower</td> <td style="text-align: left;">int</td> <td>instantly total active power</td> </tr> <tr> <td style="text-align: left;">instantlyTotalReactivePower</td> <td style="text-align: left;">int</td> <td>instantly total reactive power</td> </tr> <tr> <td style="text-align: left;">instantaneousTotalApparentPower</td> <td style="text-align: left;">int</td> <td>Instantaneous total apparent power</td> </tr> <tr> <td style="text-align: left;">powerFactor</td> <td style="text-align: left;">int</td> <td>Total power factor</td> </tr> <tr> <td style="text-align: left;">gridFrequency</td> <td style="text-align: left;">int</td> <td>grid frequency</td> </tr> <tr> <td style="text-align: left;">positiveActiveTotalEnergy</td> <td style="text-align: left;">int</td> <td>positive active total energy</td> </tr> <tr> <td style="text-align: left;">reverseActiveTotalEnergy</td> <td style="text-align: left;">int</td> <td>Reverse active total energy</td> </tr> <tr> <td style="text-align: left;">CHNT three-way meter</td> <td style="text-align: left;"></td> <td></td> </tr> <tr> <td style="text-align: left;">voltageUab</td> <td style="text-align: left;">int</td> <td>Three-phase line voltage Uab</td> </tr> <tr> <td style="text-align: left;">voltageUbc</td> <td style="text-align: left;">int</td> <td>Three-phase line voltage Ubc</td> </tr> <tr> <td style="text-align: left;">voltageUca</td> <td style="text-align: left;">int</td> <td>Three-phase line voltage Uca</td> </tr> <tr> <td style="text-align: left;">voltageUa</td> <td style="text-align: left;">int</td> <td>Three-phase phase voltage Ua</td> </tr> <tr> <td style="text-align: left;">voltageUb</td> <td style="text-align: left;">int</td> <td>Three-phase phase voltage Ub</td> </tr> <tr> <td style="text-align: left;">voltageUc</td> <td style="text-align: left;">int</td> <td>Three-phase phase voltage Uc</td> </tr> <tr> <td style="text-align: left;">currentIa</td> <td style="text-align: left;">int</td> <td>Three-phase current Ia</td> </tr> <tr> <td style="text-align: left;">currentIb</td> <td style="text-align: left;">int</td> <td>Three-phase current Ib</td> </tr> <tr> <td style="text-align: left;">currentIc</td> <td style="text-align: left;">int</td> <td>Three-phase current Ic</td> </tr> <tr> <td style="text-align: left;">activeEnergy</td> <td style="text-align: left;">int</td> <td>Combined active power</td> </tr> <tr> <td style="text-align: left;">aActivePower</td> <td style="text-align: left;">int</td> <td>A-phase active power</td> </tr> <tr> <td style="text-align: left;">bActivePower</td> <td style="text-align: left;">int</td> <td>Phase B active power</td> </tr> <tr> <td style="text-align: left;">cActivePower</td> <td style="text-align: left;">int</td> <td>C-phase active power</td> </tr> <tr> <td style="text-align: left;">reactiveEnergy</td> <td style="text-align: left;">int</td> <td>combined reactive power</td> </tr> <tr> <td style="text-align: left;">aReactivePower</td> <td style="text-align: left;">int</td> <td>Phase A reactive power</td> </tr> <tr> <td style="text-align: left;">bReactivePower</td> <td style="text-align: left;">int</td> <td>Phase B reactive power</td> </tr> <tr> <td style="text-align: left;">cReactivePower</td> <td style="text-align: left;">int</td> <td>C-phase reactive power</td> </tr> <tr> <td style="text-align: left;">powerFactor</td> <td style="text-align: left;">int</td> <td>combined power factor</td> </tr> <tr> <td style="text-align: left;">aPowerFactor</td> <td style="text-align: left;">int</td> <td>A-phase power factor</td> </tr> <tr> <td style="text-align: left;">bPowerFactor</td> <td style="text-align: left;">int</td> <td>B-phase power factor</td> </tr> <tr> <td style="text-align: left;">cPowerFactor</td> <td style="text-align: left;">int</td> <td>C-phase power factor</td> </tr> <tr> <td style="text-align: left;">frequency</td> <td style="text-align: left;">int</td> <td>frequency</td> </tr> <tr> <td style="text-align: left;">positiveActiveTotalEnergy</td> <td style="text-align: left;">int</td> <td>positive active total energy</td> </tr> <tr> <td style="text-align: left;">reverseActiveTotalEnergy</td> <td style="text-align: left;">int</td> <td>Reverse active total energy</td> </tr> <tr> <td style="text-align: left;">error_code</td> <td style="text-align: left;">string</td> <td>0: normal return, 10001: system error, 10002: collector SN error, 10003: start date error, 10004: start date interval exceeds 7 days, 10005: device address is empty, 10006: collector does not exist</td> </tr> <tr> <td style="text-align: left;">error_msg</td> <td style="text-align: left;">string</td> <td>Error message prompt</td> </tr> </tbody> </table> <p><strong>Remarks</strong></p> <p>-The frequency of acquisition is once every 5 minutes</p>

页面列表

ITEM_HTML