Get the alarm data of a certain inverter
<p><strong>A brief description:</strong> </p>
<p>-Interface to obtain alarm data of a certain inverter
-<code>Only applicable to devices with device type 1 returned in the 3.3 interface.</code></p>
<p><strong>Request URL:</strong>
-<code>http(s)://test.growatt.com/v1/device/inverter/alarm</code></p>
<p><strong>How to request:</strong>
-get</p>
<p><strong>Parameter:</strong></p>
<table>
<thead>
<tr>
<th style="text-align: left;">Parameter name</th>
<th style="text-align: left;">Is it required</th>
<th style="text-align: left;">Type</th>
<th>Description</th>
</tr>
</thead>
<tbody>
<tr>
<td style="text-align: left;">device_sn</td>
<td style="text-align: left;">yes</td>
<td style="text-align: left;">string</td>
<td>device unique serial number (SN)</td>
</tr>
<tr>
<td style="text-align: left;">date</td>
<td style="text-align: left;">is</td>
<td style="text-align: left;">time</td>
<td>a certain date (format: xxxx-xx-xx)</td>
</tr>
<tr>
<td style="text-align: left;">page</td>
<td style="text-align: left;">No</td>
<td style="text-align: left;">int</td>
<td>Page number, default 1</td>
</tr>
<tr>
<td style="text-align: left;">perpage</td>
<td style="text-align: left;">No</td>
<td style="text-align: left;">int</td>
<td>Number per page, default 20, maximum 100</td>
</tr>
</tbody>
</table>
<p><strong>Return example</strong></p>
<pre><code>{
&quot;data&quot;: {
&quot;sn&quot;: &quot;LCB1714075&quot;,
&quot;count&quot;: 161,
&quot;alarms&quot;: [
{
&quot;alarm_code&quot;: 25,
&quot;status&quot;: 1,
&quot;end_time&quot;: &quot;2019-03-09 09:55:55.0&quot;,
&quot;start_time&quot;: &quot;2019-03-09 09:55:55.0&quot;,
&quot;alarm_message&quot;: &quot;No utility.&quot;
}
]
},
&quot;error_code&quot;: 0,
&quot;error_msg&quot;: &quot;&quot;
}</code></pre>
<p><strong>Return parameter description</strong></p>
<table>
<thead>
<tr>
<th style="text-align: left;">Parameter name</th>
<th style="text-align: left;">Type</th>
<th>Description</th>
</tr>
</thead>
<tbody>
<tr>
<td style="text-align: left;">count</td>
<td style="text-align: left;">int</td>
<td>Total number of alarms</td>
</tr>
<tr>
<td style="text-align: left;">sn</td>
<td style="text-align: left;">string</td>
<td>Device SN</td>
</tr>
<tr>
<td style="text-align: left;">alarm_code</td>
<td style="text-align: left;">string</td>
<td>alarm code</td>
</tr>
<tr>
<td style="text-align: left;">alarm_message</td>
<td style="text-align: left;">string</td>
<td>alarm information</td>
</tr>
<tr>
<td style="text-align: left;">start_time</td>
<td style="text-align: left;">time</td>
<td>Alarm start time</td>
</tr>
<tr>
<td style="text-align: left;">end_time</td>
<td style="text-align: left;">time</td>
<td>Alarm end time</td>
</tr>
<tr>
<td style="text-align: left;">error_code</td>
<td style="text-align: left;">int</td>
<td>0: normal return, 10001: system error, 10002: device serial number error</td>
</tr>
<tr>
<td style="text-align: left;">error_msg</td>
<td style="text-align: left;">string</td>
<td>Error message prompt</td>
</tr>
</tbody>
</table>
<p><strong>Remarks</strong></p>
<p>-The frequency of acquisition is once every 5 minutes</p>